Microliter™ Built-In Syringe Guide Syringes, Hamilton Company

Supplier: HAMILTON COMPANY
88507 80337 88407 86207 80407 88007 80307 80107 86254
Hamilton Company offers the most comprehensive selection of standard and custom syringes in the industry

Each is manufactured to achieve the highest level of accuracy and precision possible. The syringes in this series have a built-in syringe guide installed by the factory that prevent the plunger from bending and pulling out of the syringe. Factory installation ensures the guide is applied correctly and eliminates inadvertent damage caused by incorrect do-it-yourself assembly. These 700 and 7000 series Microliter™ syringes have a stainless steel plunger that is hand fitted to the glass barrel and are designed for liquid sampling.

A variety of different terminations and needle options are available. Cemented Needle (N)- For low volume syringes the needles are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable Needle (RN)- The needles are removable and are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. Additionally, this termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life.

Needle Point Style 2 - Sharp, beveled, curved, non-coring needle point recommended for septum penetration. Available gauges: 26s. Needle Point Style 3 - Blunt needle point for use with HPLC injection valves and for sample pipetting. Available gauges: 22s, 23s, 24, 25s.




 

ORDER

Expand All / Collapse All
Description Gauge Volume Needle Length Point Style Termination Supplier No. VWR Catalog Number Unit Price Quantity
Hamilton Model 7000.5 KHWG Syringe 25 .5 µL 69.9 mm (23/4") 3 KH 86254 89221-298 Each Retrieving Restricted
Hamilton Model 7001 KHWG Syringe 25s 1 µL 69.9 mm (23/4") 3 KH 80107 60375-138 Each Retrieving Restricted
Hamilton Model 7002 KHWG Syringe 25s 2 µL 69.9 mm (23/4") 3 KH 88407 60375-074 Each Retrieving Restricted
Hamilton Model 701 NWG Syringe 26s 10 µL 51 mm (2") 2 N 80307 60373-800 Each Retrieving Restricted
Hamilton Model 701 Small RNWG Syringe 26s 10 µL 51 mm (2") 2 RN 80337 72310-438 Each Retrieving Restricted
Hamilton Model 702 NWG Syringe 22s 25 µL 51 mm (2") 2 N 80407 89221-262 Each Retrieving Restricted
Hamilton Model 7101 KHWG Syringe 22s 1 µL 69.9 mm (23/4") 3 KH 86207 89221-296 Each Retrieving Restricted
Hamilton Model 7102 KHWG Syringe 23s 2 µL 69.9 mm (23/4") 3 KH 88507 89221-304 Each Retrieving Restricted
Hamilton Model 7105 KHWG Syringe 24 5 µL 69.9 mm (23/4") 3 KH 88007 60375-095 Each Retrieving Restricted
restricted In order to process your orders without delay, we request that you provide the required business documentation to purchase this product.

To order chemicals, medical devices, or other restricted products please provide identification that includes your business name and shipping address via email CMD_NA@vwr.com or fax 484.881.5997 referencing your VWR account number . Acceptable forms of identification are:

  • State issued document with your organization's Federal Tax ID Number
  • State issued document with your organization's Resale Tax ID Number
  • City or County issued Business License
  • State Department of Health Services License
  • Any other ID issued by the State that includes the business name and address

* Please note if your account is within the State of California two of these pieces of identification will be required.
VWR will not lift restrictions for residential shipping addresses.

Generate Barcodes Barcode Label Format: 
Generate PDF Catalog Page

SPECIFICATIONS

Fluid Path SST, Borosilicate glass
Min. Temperature 10 °C / 50 °F
Gas Sterilizable Yes

ACCESSORIES

Expand All / Collapse All

Accessories
Description O.D. Needle Gauge Size Supplier No. VWR Catalog Number Unit Price Quantity
Cleaning Concentrate, 500 mL - - - 18311 60380-806 Each Retrieving Restricted
Cleaning Concentrate, 70 mL - - - 18310 60380-781 Each Retrieving Restricted
Needle Cleaning Kit with Tungsten Cleaning Wires and 70 mL Bottle of Cleaning Concentrate 76620A 60380-759 Each Retrieving Restricted
Tungsten Needle Cleaning Wires 0.089 mm 26S and 31–33 17.8 cm 18300 72310-070 Pack of 10 Retrieving Restricted
Tungsten Needle Cleaning Wires 0.126 mm 22S, 25S, and 28–30 17.8 cm 18301 72310-068 Pack of 10 Retrieving Restricted
Tungsten Needle Cleaning Wires 0.167 mm 27 17.8 cm 18302 72310-066 Pack of 10 Retrieving Restricted
Tungsten Needle Cleaning Wires 0.207 mm 24–26 17.8 cm 18303 72310-064 Pack of 10 Retrieving Restricted
Tungsten Needle Cleaning Wires 0.306 mm 22, 23, and Larger 17.8 cm 18304 72310-062 Pack of 10 Retrieving Restricted
Generate Barcodes Barcode Label Format: 
Generate PDF Catalog Page

Enter Details

Select the article for which you are looking for Certificate

Indicate the Lot Number. This field is mandatory.

Enter Certificate Details

Enter the Lot number:

Choose from recent batch/lot numbers:

Or
Review & Compare Alternatives
We found alternative products that can save you up to  per item-unit.  To compare product details, select up to 3 alternatives below and click Compare Selected. To add items to your basket, enter a quantity and click Add to Basket.

Original Product:

Description Catalog Number Availability Unit Your Price Price Per Qty
 

A new look and a renewed commitment

Built on the features & resources you know, optimized with innovation from Avantor®. Our new brand symbolizes agility and our ability to adapt to customer needs.

Learn More Start Shopping