VWR® Standard Series Flammable Material Storage Freezers

Supplier: VWR International
VWR®
FFV-20 FFV-30 FFV-17 FFV-14
The VWR® Standard Series Flammable Freezers are designed to meet NFPA and OSHA guidelines 45 and 70 for the refrigerated storage of flammable or volatile materials in general laboratory work areas.

  • Electrical components are housed externally
  • –15 to –25 °C [freezer] temperature range
  • Adjustable operating temp range

No electrical components are located in the interior of the unit, and the electrical components of the compressor have sealed in a vapor-proof enclosure for additional safety. Standard features package includes keyed door locks and probe access port.

Certifications: UL/C-UL listed.

Ordering information: Two-year parts and labor warranty.

Services: White Glove Installation and Verification Service–the white glove installation includes unpacking, inspection, removal/disposal of packing materials, transporting order via elevator and merchandise set up in the room of your choice, installation of casters or leveling feet, power and electrical connections inspected, supply voltage verified, functional and performance verification documented. Our engineers will move the unit from the customer's receiving dock to the lab within the same building. This service does NOT include transportation from vendor warehouse to customer’s receiving dock.


 

ORDER

Expand All / Collapse All

Units
Electrical Volume Exterior Dimensions No. of Shelves Shipping Weight VWR Catalog Number Unit Price Quantity
115V, 60Hz, 5 A 396 L (14 cu. ft.) 293/4W x 341/4D x 62"H 3 Fixed 236 lbs. 10819-718 Each Retrieving
Product available on GSA Advantage® UL Listed cUL Listed
115V, 60Hz, 5 A 481 L (17 cu. ft.) 34W x 34 11/16D x 67 3/4" H 3 Fixed 261 lbs. 10819-720 Each Retrieving
Product available on GSA Advantage® UL Listed cUL Listed
115V, 60Hz, 5 A 566 L (20 cu. ft.) 34W x 351/4D x 731/4"H 4 Fixed 313 lbs. 10819-722 Each Retrieving
Product available on GSA Advantage® UL Listed cUL Listed
115V, 60Hz, 6 A 850 L (30 cu. ft.) 353/4W x 351/2D x 721/2H 4 Fixed 378 lbs. 10819-724 Each Retrieving
Product available on GSA Advantage® UL Listed cUL Listed
Generate Barcodes Barcode Label Format: 
Generate PDF Catalog Page

SPECIFICATIONS

Defrost Manual
Door Type One solid swing

ACCESSORIES

Expand All / Collapse All

Accessories
Description VWR Catalog Number Unit Price Quantity
Additional Full Shelf for 30 Cu. Ft. Model 75800-416 Each Retrieving
Generate Barcodes Barcode Label Format: 
Generate PDF Catalog Page

SERVICES


Services: White Glove Installation and Verification Service–the white glove installation includes unpacking, inspection, removal/disposal of packing materials, transporting order via elevator and merchandise set up in the room of your choice, installation of casters or leveling feet, power and electrical connections inspected, supply voltage verified, functional and performance verification documented. Our engineers will move the unit from the customer's receiving dock to the lab within the same building. This service does NOT include transportation from vendor warehouse to customer’s receiving dock.
Expand All / Collapse All

Services
Description Details Includes Service Coverage Out-of-Service Coverage VWR Catalog Number Unit Price Quantity
VWR® NIST On-Site Calibration Each device has been powered up and set temperature point for 24 hours before on-site service. Calibration at a single point using NIST traceable standards. Upon completion, a calibration form will be provided with “as found” and “as left” measurements. (50 Miles From Center City) Philadelphia, PA; New York, NY; Boston, MA; Washington, DC; Raleigh, NC; Tampa, FL; Miami, FL; Atlanta, GA; Nashville, TN; Cleveland, OH; Chicago, IL; Indianapolis, IN; Minneapolis, MN; Milwaukee, WI; St. Louis, MO; Dallas, TX; Houston, TX; Austin, TX; Denver, CO; Salt Lake City, UT; Phoenix, AZ; San Diego, CA; Los Angeles, CA; Las Vegas, NV; Portland, OR; Seattle, WA. Other service/area/brand, please visit www.vwr.com/equip_services or call 888.793.2300 to get a quote. 75875-880 Each Retrieving
VWR® NIST On-Site PM and Calibration Each device has been powered up and set temperature point for 24 hours before on-site service. PM and Calibration service includes cleaning of seals, fans, and gaskets. The chamber is inspected interiorly and exteriorly. After PM, technicians will calibrate the chamber as described in Calibration section. (50 Miles From Center City) Philadelphia, PA; New York, NY; Boston, MA; Washington, DC; Raleigh, NC; Tampa, FL; Miami, FL; Atlanta, GA; Nashville, TN; Cleveland, OH; Chicago, IL; Indianapolis, IN; Minneapolis, MN; Milwaukee, WI; St. Louis, MO; Dallas, TX; Houston, TX; Austin, TX; Denver, CO; Salt Lake City, UT; Phoenix, AZ; San Diego, CA; Los Angeles, CA; Las Vegas, NV; Portland, OR; Seattle, WA. Other service/area/brand, please visit www.vwr.com/equip_services or call 888.793.2300 to get a quote. 75875-888 Each Retrieving
VWR® NIST Traceable Validate (IOQ) IQ does not include installation. Unit must be powered up and set temperature point for 24 hours before on-site service. Validation (IQ/OQ) includes a standardized protocol procedure, calibration, tuning, IQ (verify design spec, system SOP, environmental conditions etc), and OQ (Perform empty chamber temperature mapping, open door and power loss testing). (50 Miles From Center City) Philadelphia, PA; New York, NY; Boston, MA; Washington, DC; Raleigh, NC; Tampa, FL; Miami, FL; Atlanta, GA; Nashville, TN; Cleveland, OH; Chicago, IL; Indianapolis, IN; Minneapolis, MN; Milwaukee, WI; St. Louis, MO; Dallas, TX; Houston, TX; Austin, TX; Denver, CO; Salt Lake City, UT; Phoenix, AZ; San Diego, CA; Los Angeles, CA; Las Vegas, NV; Portland, OR; Seattle, WA. Other service/area/brand, please visit www.vwr.com/equip_services or call 888.793.2300 to get a quote. 75875-950 Each Retrieving
VWR® NIST Traceable Validate (IOPQ) IQ does not include installation. Unit must be powered up and set temperature point for 24 hours before on-site service. IQ/OQ will be performed as described in the (IQ/OQ) section. The PQ consists of loaded chamber temperature mapping for an additional 24 hours. (50 Miles From Center City) Philadelphia, PA; New York, NY; Boston, MA; Washington, DC; Raleigh, NC; Tampa, FL; Miami, FL; Atlanta, GA; Nashville, TN; Cleveland, OH; Chicago, IL; Indianapolis, IN; Minneapolis, MN; Milwaukee, WI; St. Louis, MO; Dallas, TX; Houston, TX; Austin, TX; Denver, CO; Salt Lake City, UT; Phoenix, AZ; San Diego, CA; Los Angeles, CA; Las Vegas, NV; Portland, OR; Seattle, WA. Other service/area/brand, please visit www.vwr.com/equip_services or call 888.793.2300 to get a quote. 75875-942 Each Retrieving

White Glove Installation and Verification Services
Description Details Service Coverage Out-of-Service Coverage VWR Catalog Number Unit Price Quantity
White Glove, Installation and Verification Service (Unit greater than 10 ft3 capacity) Service for first unit (Unit >10 ft3 capacity) Philadelphia, PA; New York, NY; Boston, MA; Washington, DC; Raleigh, NC; Tampa, FL; Miami, FL; Atlanta, GA; Nashville, TN; Cleveland, OH; Chicago, IL; Indianapolis, IN; Minneapolis, MN; Milwaukee, WI; St. Louis, MO; Dallas, TX; Houston, TX; Austin, TX; Denver, CO; Salt Lake City, UT; Phoenix, AZ; San Diego, CA; San Francisco, CA; Los Angeles, CA; Las Vegas, NV; Portland, OR; Seattle, WA Other service/area/brand, please visit www.vwr.com/equip_services or call 888.793.2300 to get a quote 76200-342 Each Retrieving
White Glove, Installation and Verification Service (Unit greater than 10 ft3 capacity) - Adds on item Additional chambers service (>10 ft3 capacity) to be performed during same scheduled service date Philadelphia, PA; New York, NY; Boston, MA; Washington, DC; Raleigh, NC; Tampa, FL; Miami, FL; Atlanta, GA; Nashville, TN; Cleveland, OH; Chicago, IL; Indianapolis, IN; Minneapolis, MN; Milwaukee, WI; St. Louis, MO; Dallas, TX; Houston, TX; Austin, TX; Denver, CO; Salt Lake City, UT; Phoenix, AZ; San Diego, CA; San Francisco, CA; Los Angeles, CA; Las Vegas, NV; Portland, OR; Seattle, WA Other service/area/brand, please visit www.vwr.com/equip_services or call 888.793.2300 to get a quote 76200-222 Each Retrieving
Generate Barcodes Barcode Label Format: 
Generate PDF Catalog Page

Enter Details

Select the article for which you are looking for Certificate

Indicate the Lot Number. This field is mandatory.

Enter Certificate Details

Enter the Lot number:

Choose from recent batch/lot numbers:

Or
Review & Compare Alternatives
We found alternative products that can save you up to  per item-unit.  To compare product details, select up to 3 alternatives below and click Compare Selected. To add items to your basket, enter a quantity and click Add to Basket.

Original Product:

Description Catalog Number Availability Unit Your Price Price Per Qty
 

A new look and a renewed commitment

Built on the features & resources you know, optimized with innovation from Avantor®. Our new brand symbolizes agility and our ability to adapt to customer needs.

Learn More Start Shopping